DCLType |
Ceiling lamp connector |
---|
|
Designer |
IEC |
---|
Designed |
2005 (2005) |
---|
Manufacturer |
Elko, Legrand, Schneider Electric, Lébénoïd, more |
---|
|
Length |
24.2 mm + length of pins |
---|
Width |
30.2 mm |
---|
Audio signal |
None |
---|
Video signal |
None |
---|
Cable |
Electrical |
---|
Pins |
3 |
---|
Connector |
DCL |
---|
|
Signal |
6 ampere |
---|
Earth |
Yes |
---|
Max. voltage |
250 V AC |
---|
Max. current |
6 A |
---|
|
Data signal |
None |
---|
|
Pin 1 |
Load |
L |
---|
Pin 2 |
Protective earth |
PE |
---|
Pin 3 |
Neutral |
N |
---|
3 on the plug, 6 inside the socket. |
Device for Connection of Luminaires (DCL) is a European standard for ceiling light fixtures introduced in 2005 and refined in 2009. It uses 6 ampere. DCL must carry the CE marking as per the Low Voltage Directive. DCL is only allowed to be installed with ground.
Plug (external)
Pin |
Color |
Function
|
1 |
|
Load (L)
|
2 |
|
Protective earth
|
3 |
|
Neutral (N)
|
Socket internals
Pin |
Color |
Function
|
1 |
|
Load (L)
|
2 |
|
Load (L)
|
3 |
|
Protective earth
|
4 |
|
Protective earth
|
5 |
|
Neutral (N)
|
6 |
|
Neutral (N)
|
Adoption
External links